FREQUENTLY
ASKED QUESTIONS
Q: WILL TRAC’S SOLUTIONS ATTACK MY GASKETS, SEALS,
OR PLASTICS?
NO! All of our solutions are specifically formulated for these
types of applications. These materials can actually stay in
full contact with the products for several weeks without being
corrupted.
Q: WHAT ABOUT THE METALS IN MY SYSTEM?
If used as directed, our solutions will not harm metal. Metals
that should be monitored closely when using TRAC solutions are
galvanize, zinc, tin and some aluminum oxides. The aluminum
designed for uses in a water system, which most marine equipment
is, is normally compatible with Trac Products. NOTE: ZINC ANODES
WILL NEED TO BE REMOVED PRIOR TO OR REPLACED AFTER COMPLETION
OF CLEANING.
Q: DO I NEED TO RINSE AFTER THE APPLICATION?
In most cases, yes. Usually this entails starting the engine,
or turning on the air conditioning.
FOR DRINKING, BLACK, and GRAY WATER SYSTEMS: a good flush is
required because you do not want to leave the chemical in the
system for an extended amount of time.
Q: DO I NEED TO BE CAREFUL WHEN HANDLING YOUR PRODUCTS?
These products by nature will etch most metals. In other words
ANY polished aluminum, marble, or tile will lose its shine.
Covering your work area and removing deck plates is recommended.
As far as any immediate danger to the applier of our products,
TRAC solutions are safe, non-toxic, biodegradable, non-corrosive,
and non-hazardous.
Q: WHAT ABOUT CARPETS AND WOOD?
The product will react in the same manner as water would on
carpets and wood.
Q: WHEN USING THE CONCENTRATE, CAN I DILUTE IT MORE
THAN IT IS RECOMMENDED?
You can, but you will not obtain the desired results with a
diluted solution.
Q: HOW CAN I MAKE SURE THAT THE CLEANING HAS COMPLETED?
The best method is by measuring the pH level. The pH will rise
during the application as deposits are dissolved. Once the pH
has leveled off, or maintains at a set level for about 1 hour,
the solution is no longer dissolving any material and has completed
the cleaning. If a pH meter is not available, a visual inspection
of the product will work but it is not 100% reliable. Once the
foaming reduces, the application should be complete.
Q: HOW CAN I TELL IF MY PRODUCT IS STILL ACTIVE?
If you do not have access to a pH meter, try dropping a small
seashell in the solution. The shell should completely dissolve
itself within a 20 minutes time period.
Q: HOW DO I REMOVE THE PRODUCT ONCE THE CLEANING IS
DONE?
In most cases you can simply turn the equipment on and let it
flush it self out. Although all of our products are safe to
dispose of through your sewer system, you should check your
local laws on disposal.
Q: CAN I FLUSH MORE THAN ONE SYSTEM AT A TIME?
Yes, you can, that’s what’s great about TRAC! By
pumping two systems together in a series you can easily flush
both systems concurrently, saving you a lot of time.
Q: WHAT IF I CAN’T RECIRCULATE YOUR PRODUCT?
Although we always recommend trying to recirculate the product,
you can also soak the system. This will take a bit longer but
will yield the same results.